Square D (Schneider Electric)

Shop By

1337 Products found

Set Descending Direction
View as List Grid
  1. Square D (Schneider Electric) Replacement AC Magnet Coil, 208 Vac, 60Hz, For 60A Type SD and SP-NEMA Size 2 (2-3 Pole) Magnetic Contactors/Starters

    The coil can be easily replaced in a Type S contactor or starter. By changing out the coil, the contactor or starter can be used in different control circuit voltage applications. This will also save the cost of a whole new contactor or starter if the coil were to fail. This coil is used in an 8502SD contactor, an 8536SD starter or an 8903SP lighting contactor. This coil is rated for 208 VAC 60 Hz. The inrush power of this coil is 311 VA. It has an average sealed consumption of 37 VA. This coil has a height of 66.2 mm, a width of 101.1 mm and a depth of 61.7 mm. Coil is fully encapsulated to protect it. Coil has screw clamp connections.
    Login for pricing
  2. Square D (Schneider Electric) Type M Integral Horsepower Manual Starter, Non-Reversing, No Indicator, 600 Vac, NEMA 1, 3-Pole, Size M-1, Square Pushbutton

    2510M and T integral horsepower manual motor starters provide overload protection and On Off control for small AC motors. These non-reversing integral horsepower manual starters are used in a variety of industrial and commercial installations. Typical applications include fans, conveyors, pumps, and small machine tools. Overload heater elements are ordered separately to match motor data. This NEMA Size M-1 three pole starter is rated for 7.5 HP at 200-230 VAC and 10 HP at 380-575 VAC three phase. Three melting alloy thermal units are used with this manual starter to sense over current conditions. These thermal units are ordered separately to match motor data. The pressure wire clamp terminals will accept 14 to 8 AWG copper wire. This starter has no pilot light indicator. A NEMA 1 general purpose surface mount enclosure is used to protect this integral horsepower manual starter. This is a painted sheet steel enclosure. Enclosure is 8.63 inches tall, 5.00 inches wide and 4.13 inches deep
    Login for pricing
  3. Square D (Schneider Electric) Manual Switch, Open, 2-Pole, Toggle Operated, No Indicator, 600VAC

    2510K manual motor switches are Intended for industrial, commercial and residential applications. These switches are for applications where overload protection is not required or is provided separately. Manual motor switches provide manual On Off control of small motors. A variety of enclosures are available. This nonreversing manual switches is toggle operated. The maximum operational voltage is 600 VAC and 250 VDC. This two pole switch is rated for 2 HP at 115VAC, 2 HP at 230VAC, 3 HP at 460VAC, 3 HP at 600VAC single phase, 1 HP at 90 VDC, 2 HP at 115 VDC and 1.5 HP at 230 VDC and 30A continuous. The screw clamp terminals will accept 14 to 10 AWG copper wire. This switch has no pilot light indicator. This manual motor switch is not supplied with an enclosure. This switch is 4.13 inches tall, 1.69 inches wide and 2.34 inches deep. It weighs 0.35 lb. This device is UL Listed and CSA certified.
    Login for pricing
  4. Square D (Schneider Electric) Manual starter, Manual Switch, handle guard, with padlock provision, for 2510 F and K manual devices

    2510F fractional horsepower non-reversing manual starters provides manual On-Off control with overload protection for small motors. The kit provides a provision for a padlock. The kit can be added by mounting it under the cover screws of the NEMA 1 enclosure or the flush plate. This kit is supplied as standard on 2510K manual switches. Melting alloy thermal units are used with this manual starter to sense over current conditions.
    Login for pricing
  5. Square D (Schneider Electric) Transformer, dry type, encapsulated, 10kVA, 1 phase, 240x480V primary, 120/240V secondary, 13B, 115C rise [TAA, BAA, BABA, BAA_COTS]

    Resin Encapsulated Transformers, these general purpose transformers accommodate voltage systems world wide. Resin-filled general purpose transformers are epoxy encapsulated. The enclosure has no openings, making resin-filled transformers ideal for use indoor or outdoor where airborne particles or contaminants could be detrimental to operation. The core-and-coil assembly is embedded in an epoxy resin compound and wall mounted for maximum protection. Type 3R enclosure are designed to allow energy efficient transformers to be installed in environments requiring more protection. This Dry Sealed Transformer that is 1 phase, and has a rated power of 10 KVA. This transformer has a primary voltage of 240 x 480 V, and a secondary voltage of 120/240 V. The enclosure for this transformer has a NEMA 3R rating, and is wall mounted, and made of painted sheet steel. Dimensions for this transformer are 14.75 in (H), 9.75 in (W), 11.75 in (D). This product complys to UL CSA standards.
    Login for pricing
  6. Square D (Schneider Electric) PowerPact8482 Molded Case Circuit Breaker, Q-Frame, Thermal Magnetic, Unit Mount, 10kA, 240 Vac, 3-Pole, 200A

    PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has lugs on both the line and load sides. This PowerPacT Q, 200A, 3 pole, circuit breaker has an interrupting rating of 10kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
    Login for pricing
  7. Square D (Schneider Electric) PowerPact8482 Molded Case Circuit Breaker, Q-Frame, Thermal Magnetic, Unit Mount, 10kA, 240 Vac, 3-Pole, 125A

    PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has lugs on both the line and load sides. This PowerPacT Q, 125A, 3 pole, circuit breaker has an interrupting rating of 10kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
    Login for pricing
  8. Square D (Schneider Electric) QO Load Center Retaining Kit

    QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. They are designed to meet residential, commercial, and industrial requirements to protect electrical systems, equipment, and people. This part has been verified to adhere the data sheet specifications by the Underwriters Laboratories (UL) Listed and CSA.
    Login for pricing
  9. Square D (Schneider Electric) QO Load Center Retaining Kit

    QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. They are designed to meet residential, commercial, and industrial requirements to protect electrical systems, equipment, and people. This part has been verified to adhere the data sheet specifications by the Underwriters Laboratories (UL) Listed and CSA.
    Login for pricing
  10. Square D (Schneider Electric) QO Load Center Equipment Ground Bar Kit, 18 Terminal

    QO® Circuit Breaker Load Centers, PK18GTA, from Square D® are Underwriters Laboratories (UL) Listed and CSA rated panelboards. They are designed to meet residential, commercial, and industrial requirements to protect electrical systems, equipment, and people. All metering stacks are shipped from the factory with meter sockets and vertical bus bars pre-installed, and require a minimum of on site labour to install the circuit breakers and main bus links. Provision to lock and seal the circuit breaker handles in the “off” position has been made for the convenience of utilities and electrical inspectors. This 247/600V and 3 phases unit is avaible with 500A vertical bus bar. 3-pole Powerpact H-frame circuit breakers are required for the 125A, 7- jaw sub-service sections and are available from 60A-125A. The unit comes in sizes of height 79.62 in, 15.33 in width and 6.5 in of depth. All meter stacks are designed for CSA Type A “cold metering” in which the individ
    Login for pricing

1337 Products found

Set Descending Direction
View as List Grid