Square D (Schneider Electric)

Shop By

1337 Products found

Set Descending Direction
View as List Grid
  1. Square D (Schneider Electric) NF Panelboard Interior, Main Lug, 400A, 277/480Y, 3-Phase, 30 Spaces

    NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 400A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Lug connections will accept 1/0 AWG to 750 kcmil aluminum wire. The interior is 46 inches tall and 10.44 inches wide.
    Login for pricing
    Out of stock
  2. Square D (Schneider Electric) Panelboard interior, NF, main lugs, 125A, Cu bus, 18 pole spaces, 3 phase, 4 wire, 600Y/347VAC max

    NF Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These interiors provide protection for commercial and industrial applications. NF Panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. NF Panelboards are field convertible to top or bottom feed. NF Panelboards are convertible from main lug to main breaker. NF Panelboards can provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. The main lugs are rated at 125A 480Y/277 VAC 3 phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 18 spaces and has a copper bus bar. Interior is for EDB, EDG, and EDJ branch circuit breakers. Lug connections will accept 6 AWG to 2/0 AWG copper or aluminum wire. The interior is 21 inches tall and 10.44 inches
    Login for pricing
    Out of stock
  3. Square D (Schneider Electric) Panelboard Accessory, Panelboard Enclosure Cover, NEMA Type 1, Surface Mount, Hinged Front, 20 in. W, 68 in. H

    NF NQ Panelboards can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These panelboards provide protection for commercial and industrial applications. These versatile panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. This steel NEMA 1 rated cover is for NF and NQ panelboards. This grey surface cover has a hinge on the right. This surface cover is 68 inches tall and 20 inches wide. This panelboard cover is UL Listed and CSA certified by UL.
    Login for pricing
    Out of stock
  4. Square D (Schneider Electric) NQNF Panelboard Enclosure Surface Cover, NEMA 1, Hinged, 20 x 32 in.

    Square D® NQ/NQM panelboards, NC32SHR, is a grey hinged steel surfface cover. has NEMA1 degree of protection, cULus certified. Warranty period is 18 month. .
    Login for pricing
    Out of stock
  5. Square D (Schneider Electric) Panelboard enclosure box, NQ/NF, Type 1, blank end walls, 62in H x 20in W x 5.75in D

    NQ and NF Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ and NF Panelboards provide 200% rated neutrals for nonlinear loads. NQ and NF Panelboards are convertible from main lug to main breaker. NQ and NF Panelboards have many different options for your enclosure box. This enclosure box is rated as a type 1 with blank end walls. The dimensions for this box are 20 x 62 x 5.75 in. NQ and NF Panelboard interiors are field convertible to top or bottom feed. NQ and NF Panelboards are suitable for use as service equipment. Panelboard enclosure box is UL listed and CSA certified by UL.
    Login for pricing
    Out of stock
  6. Square D (Schneider Electric) Panelboard Enclosure, NEMA 1, Knockouts, 20 W x 62 H x 5-3/4 in. D

    Square D® NF Merchandised Panelboards MH62, is a enclosure steel panelboard box has NEMA1 degree of protection, cULus certified. Warranty period is 18 month. .
    Login for pricing
    Out of stock
  7. Square D (Schneider Electric) Panelboard enclosure box, NQ/NF, Type 1, 20in W x 38in H x 5.75in D, [TAA, BAA, BABA, BAA_COTS]

    Square D® NF Merchandised Panelboards MH38, is a enclosure steel panelboard box has NEMA1 degree of protection, cULus certified. Warranty period is 18 month.
    Login for pricing
    Out of stock
  8. Square D (Schneider Electric) Multi 9 C60<sub>BP</sub> Miniature Circuit Breaker, Tunnel Terminal Connection, 480Y/277V, 2-Pole, D-Curve, 20A

    This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 20A rated current and D tripping curve. The rated short circuit breaking capacity goes up to 10kA at 415VAC conforming to EN/IEC 60947-2 standard and 10kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail.
    Login for pricing
    Out of stock
  9. Square D (Schneider Electric) TeSys Deca Thermal Overload Relays , 17...25A , Class 10A

    LRD3322 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 9-11kW@400V thanks to a thermal range 17-25A, a tripping class 10A and phase unbalance protection. LRD3322 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 17-25A, a tripping class 10A and phase unbalance detection, it protects motors 11kW@400V. It provides manual test reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D80 and D95 to form a compact starter. Light and compact, 70mm wide. Temperature compensated for a good accuracy of the protection. Manual control with
    Login for pricing
    Out of stock
  10. Square D (Schneider Electric) Panelboard accessory, NF, key

    Square Dâ„¢ NF Accerories, LP9618, key NSR-251, for use on all locks except those on stainless steel enclosures.
    Login for pricing
    Out of stock

1337 Products found

Set Descending Direction
View as List Grid