Square D (Schneider Electric)

Shop By

1337 Products found

Set Descending Direction
View as List Grid
  1. Square D (Schneider Electric) NQNF Panelboard Enclosure Surface Cover, NEMA 1, Hinged, 20 x 26 in.

    Square D® NQ/NQM panelboards, NC26SHR, is a grey hinged steel surfface cover. has NEMA1 degree of protection, cULus certified. Warranty period is 18 month. .
    Login for pricing
  2. Square D (Schneider Electric) Panelboard Cover, Surface Mount, For 26 in. H NF Panelboards

    NF NQ Panelboards can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. These panelboards provide protection for commercial and industrial applications. These versatile panelboards feature a wide selection of circuit breakers, accessories, and ready to install kits. This steel NEMA 1 rated cover is for NF and NQ panelboards. This surface cover is painted grey. This surface cover is 26 inches tall and 20 inches wide. This panelboard cover is UL Listed and CSA certified by UL.
    Login for pricing
  3. Square D (Schneider Electric) Panelboard Main Breaker Mounting Kit, 400A, For NF Panelboards

    NF Panelboards provide a broad range of solutions available from distributor stock to address electrical contractor's need. NF Panelboards have modular construction to accept field installable accessories and conversion kits. This panelboard accessory is a installation kit used for main breakerss This kit is rated at 400 A and is for LI, LC, LAL and LHL circuit breakers.
    Login for pricing
  4. Square D (Schneider Electric) Panelboard Enclosure, NEMA 3R/5/12, 20 W x 38 H x 6-1/2 in. D

    NQ and NF Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ and NF Panelboards provide 200% rated neutrals for nonlinear loads. NQ and NF Panelboards are convertible from main lug to main breaker. NQ and NF Panelboards have many different options for your enclosure box. This enclosure box is rated as a type 3R/5/12. The dimensions for this box are 20 x 38 x 6.50 in. NQ and NF Panelboard interiors are field convertible to top or bottom feed. NQ and NF Panelboards are suitable for use as service equipment. Panelboard enclosure box is UL listed and CSA certified by UL.
    Login for pricing
  5. Square D (Schneider Electric) Panelboard Enclosure, NEMA 1, Blank End Walls, 20 W x 26 H x 5-3/4 in. D

    NQ and NF Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ and NF Panelboards provide 200% rated neutrals for nonlinear loads. NQ and NF Panelboards are convertible from main lug to main breaker. NQ and NF Panelboards have many different options for your enclosure box. This enclosure box is rated as a type 1 with blank end walls. The dimensions for this box are 20 x 26 x 5.75 in. NQ and NF Panelboard interiors are field convertible to top or bottom feed. NQ and NF Panelboards are suitable for use as service equipment. Panelboard enclosure box is UL listed and CSA certified by UL.
    Login for pricing
  6. Square D (Schneider Electric) Multi 9 C60<sub>BP</sub> Miniature Circuit Breaker, Tunnel Terminal Connection, 277V, 1-Pole, C-Curve, 15A

    This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 15A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. It
    Login for pricing
  7. Square D (Schneider Electric) Multi 9 C60<sub>BP</sub> Miniature Circuit Breaker, Tunnel Terminal Connection, 277V, 1-Pole, C-Curve, 10A

    This Multi9 C60BP is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 10A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 3kA at 415VAC conforming to EN/IEC 60947-2 standard and 3kA at 415VAC conforming to EN/IEC 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The product can be clipped on a DIN rail. It
    Login for pricing
  8. Square D (Schneider Electric) Auxiliary Contact (Spring) OF/SD - 1 NO/NC

    It is a single standard auxiliary contact that provides two remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. The SD contact (trip indication) indicates if the circuit breaker has tripped. There is one auxiliary contact model for OF and SD information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard.
    Login for pricing
  9. Square D (Schneider Electric) TeSys Motor Starter Auxilliary Contact Block, U-Line, Screw Terminals, 2NO

    TeSys U auxiliary signaling contact block for TeSys U starter controllers. It provides 1NO contact for open/close status (OF contact) and 1NO contact for tripping status (SD contact), rated up to 5A 250V AC/DC. To be inserted in the provided location of the power base. Green Premium compliant (RoHS/REACh).
    Login for pricing
  10. Square D (Schneider Electric) TeSys Deca, thermal overload relay, 48 to 65 A, Class 10A, EVERLINK

    TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 40 amp through 65 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 48 to 65 amperes. This trip current rating is calibrated per Class 10A. This overload relay uses EVERLINK termnals in place of the standard terminals.
    Login for pricing

1337 Products found

Set Descending Direction
View as List Grid