Crouse Hinds (Eaton)
Shop By
-
Crouse Hinds (Eaton) Hazardous Location Coupling, Brass with Bronze Braid, Rigid/IMC Conduit, Male/Male, 3/4 x 18 in.
ECGJH Series CouplingsRugged design to withstand explosive pressure (Class I)Mechanical abuseLiquidtight for wet locationsFor use where lack of space makes use of rigid conduit difficultNo bonding jumpers required metallic braid provides continuous electrical pathECGJH combination has two threaded male end fittingsBrass Construction with Bronze BraidClass I, Division 1, Groups A, B, C, D, Class II, Division 1, Groups E, F, G Class IIIUL Listed UL1203 -
Crouse Hinds (Eaton) Box Cover, Cast Iron or Aluminum Device Box, 1-Gang, Sheet Steel, GFCI
Surface mountFor use with cast iron or aluminum device boxes -
Crouse Hinds (Eaton) Raintight Snap Switch Cover, Die Cast Aluminum, 1-Gang
Raintight covers used on cast iron or aluminum device boxes for general use snap switches. -
Crouse Hinds (Eaton) Compression Straight Connector, Non-Insulated, Malleable Iron, Rigid/IMC Conduit, 3-1/2 in.
Threadless Compression ConnectorMalleable Iron BodyIron Compression NutsZinc Plated Steel Compression RingsZinc Plated Steel LocknutsNylon InsulinersJoins rigid or IMC conduit to a box or an enclosureCan be used in new work in poured concreteCan be used in maintenance, repairs and alterationsCan be used at panels and boxesCan be used in new, altered or damaged stub upsCan be used in locations where field threading is impractical or undesirableUnequaled versatility for the installerUnique gland ring tightens up in fewer turnsGland ring proves outstanding pull out strengthGland ring saves time and adds confidenceConcrete tightUL Listed 514B for fittings and outlet boxescUL Listed -
Crouse Hinds (Eaton) Compression Coupling, Malleable Iron, Rigid/IMC Conduit, 1 in.
Threadless Compression CouplingMalleable Iron BodyIron Compression NutsZinc Plated Steel Compression RingsZinc Plated Steel LocknutsNylon InsulinersJoins two lengths of rigid or IMC conduitCan be used in new work in poured concreteCan be used in maintenance, repairs and alterationsCan be used in locations where field threading is impractical or undesirableUnequaled versatility for the installerUnique gland ring tightens up in fewer turnsGland ring proves outstanding pull out strengthGland ring saves time and adds confidenceConcrete tightUL ListedcUL Listed -
Crouse Hinds (Eaton) Cord Connector, Zinc Electroplated Steel, Straight, Flexible Cord and Tray Cable, 1.188 to 1.375 in., 1-1/2 in.
Cord ConnectorZinc Electroplated Steel Body and Gland NutChromate FinishUse with S, SO, STO, ST, SJ, SJT, SJTO and SVO Flexible CordUse with TC, TC-ER, ITC, ITC-ER, ITC-HL, PLTC ad PLTC-ER Tray CableRugged durable construction protects cords and cables from damageCompact design permits close grouping of several cords and cablesNeoprene brushing provides a weatherproof seal on outer sheath of cablecULus Listed E23223Suitable for Use in Class I, Division 2 Hazardous Locations in Accordance with NEC501.10(B)(4)NEMA 3R - Suitable for use in wet locations -
Crouse Hinds (Eaton) Cord Connector, Zinc Electroplated Steel, Straight, Flexible Cord and Tray Cable, 0.500 to 0.625 in., 3/4 in.
Cord ConnectorZinc Electroplated Steel Body and Gland NutChromate FinishUse with S, SO, STO, ST, SJ, SJT, SJTO and SVO Flexible CordUse with TC, TC-ER, ITC, ITC-ER, ITC-HL, PLTC ad PLTC-ER Tray CableRugged durable construction protects cords and cables from damageCompact design permits close grouping of several cords and cablesNeoprene brushing provides a weatherproof seal on outer sheath of cablecULus Listed E23223Suitable for Use in Class I, Division 2 Hazardous Locations in Accordance with NEC501.10(B)(4)NEMA 3R - Suitable for use in wet locations